| Availability: | |
|---|---|
| Quantity: | |
FWC-12
folansi
FWC-12
| Name:Water source heat pump(Heating and cooling) | ||||||
| Model | Unit | FWC-10 | FWC-12 | |||
| Rated heating | Heating capacity | kw | 30 | 34 | ||
| BTU/h | 102389 | 116041 | ||||
| Input power | kw | 7.8 | 9.1 | |||
| Input current | A | 15.8 | 18 | |||
| COP | kw/kw | 3.8 | 3.8 | |||
| Rated cooling | Rated cooling capacity | kw | 27.1 | 32.9 | ||
| BTU/h | 92491 | 112287 | ||||
| Rated input power | kw | 5.8 | 7.1 | |||
| Rated input current | A | 11.6 | 14.2 | |||
| EER | kw/kw | 4.7 | 4.6 | |||
| Max running current | A | 24 | 32 | |||
| Power source | V/Hz | 380-415V/50Hz | ||||
| Nosie level | dB(A) | ≤60 | ||||
| Dimension | w*d*h | mm | 800*1080*1050 | 800*1080*1050 | ||
| Weight | kg | 260 | 300 | |||
| Precision of temp controll | ±2 | |||||
| Controller | Type | Multi-color backlight LCD, Can accept panel buttons and infrared remote control | ||||
| Main function | Working mode control, independent working temperature setting, status display, timer start and stop machine Settings, key lock function, muti-color backlight selection, etc | |||||
| Refrigeration circulation structure | Throttle type | External equalizer thermal expansion valve | ||||
| Refrigeration | Type | R410A/R32 | ||||
| Compressor | Type | Copeland,Sanyo,Daikin | ||||
| Qty | Piece | 1 | ||||
| Water source side heat exchange | Type | Efficient tube in tube heat exchanger/plate heat exchanger | ||||
| Water flow | m3/h | 2.57 | 3.12 | |||
| Water pressure drop | kPa | 14 | 16 | |||
| Pipe size | Inch | 1-1∕4 | 1-1∕4 | |||
| Water side max working pressure | kPa | 1000 | ||||
| Water chiller heat exchanger | Type | Efficient tube in tube heat exchanger/plate heat exchanger | ||||
| Water flow | m3/h | 4.66 | 5.65 | |||
| water pressure drop | kPa | 14 | 16 | |||
| Pipe size | Inch | 1-1∕4 | 1-1∕4 | |||
| Water side max working pressure | kPa | 1000 | ||||
| Refrigeration system | Too high gas temperature protection,high pressure protection, low pressure protection, sensor fault protection | |||||
| Compressor delay start protection, phase sequence protection, smoke and fire protection | ||||||
| Water source system | Water temperature protection, water flow protection, heat exchanger antifreeze protection, standby low temperature protection,Leakage protection | |||||
Rated heating working condtion:water source side water inlet temp is 15℃,use side water inlet temp is 40℃.water flow the same to summer water flow
2. Rated cooling working: water source side water inlet temp is 18℃,outlet water temp 29℃,use side water inlet water temp 12 ℃,outlet temp 7℃
| Name:Water source heat pump(Heating and cooling) | ||||||
| Model | Unit | FWC-10 | FWC-12 | |||
| Rated heating | Heating capacity | kw | 30 | 34 | ||
| BTU/h | 102389 | 116041 | ||||
| Input power | kw | 7.8 | 9.1 | |||
| Input current | A | 15.8 | 18 | |||
| COP | kw/kw | 3.8 | 3.8 | |||
| Rated cooling | Rated cooling capacity | kw | 27.1 | 32.9 | ||
| BTU/h | 92491 | 112287 | ||||
| Rated input power | kw | 5.8 | 7.1 | |||
| Rated input current | A | 11.6 | 14.2 | |||
| EER | kw/kw | 4.7 | 4.6 | |||
| Max running current | A | 24 | 32 | |||
| Power source | V/Hz | 380-415V/50Hz | ||||
| Nosie level | dB(A) | ≤60 | ||||
| Dimension | w*d*h | mm | 800*1080*1050 | 800*1080*1050 | ||
| Weight | kg | 260 | 300 | |||
| Precision of temp controll | ±2 | |||||
| Controller | Type | Multi-color backlight LCD, Can accept panel buttons and infrared remote control | ||||
| Main function | Working mode control, independent working temperature setting, status display, timer start and stop machine Settings, key lock function, muti-color backlight selection, etc | |||||
| Refrigeration circulation structure | Throttle type | External equalizer thermal expansion valve | ||||
| Refrigeration | Type | R410A/R32 | ||||
| Compressor | Type | Copeland,Sanyo,Daikin | ||||
| Qty | Piece | 1 | ||||
| Water source side heat exchange | Type | Efficient tube in tube heat exchanger/plate heat exchanger | ||||
| Water flow | m3/h | 2.57 | 3.12 | |||
| Water pressure drop | kPa | 14 | 16 | |||
| Pipe size | Inch | 1-1∕4 | 1-1∕4 | |||
| Water side max working pressure | kPa | 1000 | ||||
| Water chiller heat exchanger | Type | Efficient tube in tube heat exchanger/plate heat exchanger | ||||
| Water flow | m3/h | 4.66 | 5.65 | |||
| water pressure drop | kPa | 14 | 16 | |||
| Pipe size | Inch | 1-1∕4 | 1-1∕4 | |||
| Water side max working pressure | kPa | 1000 | ||||
| Refrigeration system | Too high gas temperature protection,high pressure protection, low pressure protection, sensor fault protection | |||||
| Compressor delay start protection, phase sequence protection, smoke and fire protection | ||||||
| Water source system | Water temperature protection, water flow protection, heat exchanger antifreeze protection, standby low temperature protection,Leakage protection | |||||
Rated heating working condtion:water source side water inlet temp is 15℃,use side water inlet temp is 40℃.water flow the same to summer water flow
2. Rated cooling working: water source side water inlet temp is 18℃,outlet water temp 29℃,use side water inlet water temp 12 ℃,outlet temp 7℃