FA-05
folansi
FA-05
Name:Air to water heat pump(60degree)heating+hot water | |||||
Model | unit | FA-05 | FA-06 | ||
Rated heating capacity | KW | 19 | 23 | ||
BTU | 64846 | 78498 | |||
Hot water supply | T/h | 0.41 | 0.46 | ||
Average heating input power | KW | 4.1 | 4.68 | ||
Rated heating input current | A | 6.66 | 12 | ||
Max outlet water temp | ℃ | 60℃ | |||
COP | 4.67 | 4.7 | |||
Power | V/Hz | 380-415V/50HZ | |||
Nosie | dB(A) | 52 | 52 | ||
Dimension | Width | mm | 834 | 834 | |
Deepth | mm | 460 | 460 | ||
Height | mm | 1330 | 1330 | ||
Unit weight | KG | 155 | 225 | ||
Throttling type | Electronic expansion valves/thermal expansion valves | ||||
Refrigerant | R410A/R32 | ||||
Working air temp range | – 20℃~45℃ | ||||
Compressor | Type | Copeland,.hitachi,panasonic | |||
Security functions | Built-in protection device overheating protection, sequence protection, undervoltage protection, delay protect | ||||
Air source heat exchanger | Type | Finned heat exchange | |||
Qty | piece | 1 | |||
Fan type | Axial big twist Angle fan | ||||
Motor power | KW | 0.3 | 0.37 | ||
Hot water side heat exchange | Type | Efficient tube to tube heat exchanger/tube in shell heat exchanger | |||
Water flow | m3/H | 3.27 | 3.72 | ||
Water pressure down | kPa | 30 | 32 | ||
Pipe size | Inch | 1 | |||
Water side max working pressure | kPa | 1000 | |||
Remarks:the test conditions of above parameter:dry bulb temp is 20℃.wet buld temp is 17℃.inlet water temp is 15℃.outlet water temp is 60℃ |
Name:Air to water heat pump(60degree)heating+hot water | |||||
Model | unit | FA-05 | FA-06 | ||
Rated heating capacity | KW | 19 | 23 | ||
BTU | 64846 | 78498 | |||
Hot water supply | T/h | 0.41 | 0.46 | ||
Average heating input power | KW | 4.1 | 4.68 | ||
Rated heating input current | A | 6.66 | 12 | ||
Max outlet water temp | ℃ | 60℃ | |||
COP | 4.67 | 4.7 | |||
Power | V/Hz | 380-415V/50HZ | |||
Nosie | dB(A) | 52 | 52 | ||
Dimension | Width | mm | 834 | 834 | |
Deepth | mm | 460 | 460 | ||
Height | mm | 1330 | 1330 | ||
Unit weight | KG | 155 | 225 | ||
Throttling type | Electronic expansion valves/thermal expansion valves | ||||
Refrigerant | R410A/R32 | ||||
Working air temp range | – 20℃~45℃ | ||||
Compressor | Type | Copeland,.hitachi,panasonic | |||
Security functions | Built-in protection device overheating protection, sequence protection, undervoltage protection, delay protect | ||||
Air source heat exchanger | Type | Finned heat exchange | |||
Qty | piece | 1 | |||
Fan type | Axial big twist Angle fan | ||||
Motor power | KW | 0.3 | 0.37 | ||
Hot water side heat exchange | Type | Efficient tube to tube heat exchanger/tube in shell heat exchanger | |||
Water flow | m3/H | 3.27 | 3.72 | ||
Water pressure down | kPa | 30 | 32 | ||
Pipe size | Inch | 1 | |||
Water side max working pressure | kPa | 1000 | |||
Remarks:the test conditions of above parameter:dry bulb temp is 20℃.wet buld temp is 17℃.inlet water temp is 15℃.outlet water temp is 60℃ |