FAD-10
folansi
FAD-10
DC Inverter Air to Water heat pump | ||||
Model | FAD-10 | FAD-12 | ||
Technical Parameters | Heating capacity (A7/W35) | kW | 27.0 | 32.8 |
Heating power input | kW | 5.66 | 6.99 | |
COP (A7/W35) | 4.77 | 4.69 | ||
Heating capacity (A7/W55) | kW | 22.9 | 27.8 | |
Heating power input | kW | 8.12 | 10.1 | |
COP (A7/W55) | 2.82 | 2.75 | ||
Heating capacity (A2/W35) | kW | 24 | 29.2 | |
Heating power input | kW | 5.58 | 6.83 | |
COP (A2/W35) | 4.30 | 4.28 | ||
Heating capacity (A2/W55) | kW | 21.5 | 26.2 | |
Heating power input | kW | 7.76 | 9.69 | |
COP (A2/W55) | 2.77 | 2.70 | ||
Heating capacity (A-7/W35) | kW | 19.4 | 23.6 | |
Heating power input (A- | kW | 5.35 | 6.64 | |
COP (A-7/W35) | 3.63 | 3.55 | ||
Heating capacity (A-7/W55) | kW | 16.2 | 19.6 | |
Heating power input (A- | kW | 7.82 | 9.78 | |
COP (A-7/W55) | 2.07 | 2.00 | ||
Heating capacity (A-15/W35) | kW | 15.8 | 19.1 | |
Heating power input (A- | kW | 5.49 | 6.85 | |
COP (A-15/W35) | 2.88 | 2.79 | ||
Heating capacity (A-15/W55) | kW | 14.7 | 17.7 | |
Heating power input (A- | kW | 8.41 | 10.38 | |
COP (A-15/W55) | 1.75 | 1.71 | ||
Cooling capacity (A35/W7) | kW | 22.4 | 27.1 | |
Cooling power input | kW | 6.71 | 8.38 | |
EER (A35/W7) | 3.34 | 3.23 | ||
operating ambient temperature | .+43 ~ --25 | |||
Max. water temp. | ℃ | 60 | ||
Rated water temp. | ℃ | 55 | ||
water flow | m3/h | 4.30 | 4.30 | |
pressure drop | Kpa | 34 | 34 | |
Net weight | kg | 210 | 210 | |
Gross weight | kg | 230 | 230 | |
Noise | dB(A) | 58 | 58 | |
Pipe connection | mm | 1-1/4 inch | ||
Power supply | 380V/3PH/50Hz | 380V/3PH/50Hz | ||
Net size | mm | 1300*480*1400 | 1300*480*1400 | |
Package size | mm | 1390*550*1540 | 1390*550*1540 | |
Standard Features | Compressor | brand | Mitsubishi | |
quantity | 1 | |||
Condenser | plate heat exchanger | |||
Evaporator | Louverd&hydrophilic fin-tubes | |||
4-way valve | Yes | |||
Flow switch | Yes | |||
Circulation pump | Built-in energy clasee A water pump | |||
Expansion valve | Electionic expansion valve | |||
DC Fan motor | 170W*2 | 170W*2 | ||
High pressure switch | 4.2/3.6MPa | |||
Low pressure switch | 0.02/0.15MPa | |||
Working mode | cooling, heating, hot water, cooling+hot water, heating+hot water | |||
Refrigerant | R32/ R410A |
1. Unit working temperature : -25℃ to 43℃
2. Test condition:
* Ambient temp: 7℃/6℃, water inlet/outlet: 30℃/35℃
** Ambient temp: 2℃/1℃, water inlet/outlet: 30℃/35℃
*** Ambient temp: 35℃, water inlet/outlet: 7℃/12℃
**** Ambient temp: 35℃, water inlet/outlet: 18℃/23℃
3. Hot water supply: the volume of hot water heated from 15℃ to 55℃ at ambient temp 15℃.
4. The above is the basic configuration. Water pump is included in.
DC Inverter Air to Water heat pump | ||||
Model | FAD-10 | FAD-12 | ||
Technical Parameters | Heating capacity (A7/W35) | kW | 27.0 | 32.8 |
Heating power input | kW | 5.66 | 6.99 | |
COP (A7/W35) | 4.77 | 4.69 | ||
Heating capacity (A7/W55) | kW | 22.9 | 27.8 | |
Heating power input | kW | 8.12 | 10.1 | |
COP (A7/W55) | 2.82 | 2.75 | ||
Heating capacity (A2/W35) | kW | 24 | 29.2 | |
Heating power input | kW | 5.58 | 6.83 | |
COP (A2/W35) | 4.30 | 4.28 | ||
Heating capacity (A2/W55) | kW | 21.5 | 26.2 | |
Heating power input | kW | 7.76 | 9.69 | |
COP (A2/W55) | 2.77 | 2.70 | ||
Heating capacity (A-7/W35) | kW | 19.4 | 23.6 | |
Heating power input (A- | kW | 5.35 | 6.64 | |
COP (A-7/W35) | 3.63 | 3.55 | ||
Heating capacity (A-7/W55) | kW | 16.2 | 19.6 | |
Heating power input (A- | kW | 7.82 | 9.78 | |
COP (A-7/W55) | 2.07 | 2.00 | ||
Heating capacity (A-15/W35) | kW | 15.8 | 19.1 | |
Heating power input (A- | kW | 5.49 | 6.85 | |
COP (A-15/W35) | 2.88 | 2.79 | ||
Heating capacity (A-15/W55) | kW | 14.7 | 17.7 | |
Heating power input (A- | kW | 8.41 | 10.38 | |
COP (A-15/W55) | 1.75 | 1.71 | ||
Cooling capacity (A35/W7) | kW | 22.4 | 27.1 | |
Cooling power input | kW | 6.71 | 8.38 | |
EER (A35/W7) | 3.34 | 3.23 | ||
operating ambient temperature | .+43 ~ --25 | |||
Max. water temp. | ℃ | 60 | ||
Rated water temp. | ℃ | 55 | ||
water flow | m3/h | 4.30 | 4.30 | |
pressure drop | Kpa | 34 | 34 | |
Net weight | kg | 210 | 210 | |
Gross weight | kg | 230 | 230 | |
Noise | dB(A) | 58 | 58 | |
Pipe connection | mm | 1-1/4 inch | ||
Power supply | 380V/3PH/50Hz | 380V/3PH/50Hz | ||
Net size | mm | 1300*480*1400 | 1300*480*1400 | |
Package size | mm | 1390*550*1540 | 1390*550*1540 | |
Standard Features | Compressor | brand | Mitsubishi | |
quantity | 1 | |||
Condenser | plate heat exchanger | |||
Evaporator | Louverd&hydrophilic fin-tubes | |||
4-way valve | Yes | |||
Flow switch | Yes | |||
Circulation pump | Built-in energy clasee A water pump | |||
Expansion valve | Electionic expansion valve | |||
DC Fan motor | 170W*2 | 170W*2 | ||
High pressure switch | 4.2/3.6MPa | |||
Low pressure switch | 0.02/0.15MPa | |||
Working mode | cooling, heating, hot water, cooling+hot water, heating+hot water | |||
Refrigerant | R32/ R410A |
1. Unit working temperature : -25℃ to 43℃
2. Test condition:
* Ambient temp: 7℃/6℃, water inlet/outlet: 30℃/35℃
** Ambient temp: 2℃/1℃, water inlet/outlet: 30℃/35℃
*** Ambient temp: 35℃, water inlet/outlet: 7℃/12℃
**** Ambient temp: 35℃, water inlet/outlet: 18℃/23℃
3. Hot water supply: the volume of hot water heated from 15℃ to 55℃ at ambient temp 15℃.
4. The above is the basic configuration. Water pump is included in.