Availability: | |
---|---|
Quantity: | |
FAD-02
folansi
FAD-02
DC Inverter Air to Water heat pump( monoblock) | |||||
Model | FAD-02 | FAD-03-1 | FAD-03 | FAD-04 | |
Heating capacity (A7/W35) | kW | 8.2 | 11.0 | 13.9 | 15.0 |
Heating power input (A7/W35) | kW | 1.38 | 2.07 | 2.69 | 2.76 |
COP (A7/W35) | 5.94 | 5.31 | 5.17 | 5.43 | |
Heating capacity (A7/W55) | kW | 6.1 | 9.2 | 10.9 | 12.2 |
Heating power input (A7/W55) | kW | 1.95 | 2.73 | 3.79 | 3.90 |
COP (A7/W55) | 3.13 | 3.37 | 2.88 | 3.13 | |
Heating capacity (A2/W35) | kW | 6.3 | 9.1 | 11.2 | 12.6 |
Heating power input (A2/W35) | kW | 1.32 | 2.02 | 2.53 | 2.64 |
COP (A2/W35) | 4.77 | 4.50 | 4.43 | 4.77 | |
Heating capacity (A2/W55) | kW | 5.7 | 7.9 | 10.2 | 11.4 |
Heating power input (A2/W55) | kW | 1.88 | 2.76 | 3.65 | 3.76 |
COP (A2/W55) | 3.03 | 2.86 | 2.79 | 3.03 | |
Heating capacity (A-7/W35) | kW | 5.3 | 6.71 | 9.6 | 10.6 |
Heating power input (A-7/W35) | kW | 1.42 | 1.82 | 2.72 | 2.84 |
COP (A-7/W35) | 3.73 | 3.69 | 3.53 | 3.73 | |
Heating capacity (A-7/W55) | kW | 5.1 | 7.7 | 9.1 | 10.2 |
Heating power input (A-7/W55) | kW | 2.18 | 3.5 | 4.33 | 4.36 |
COP (A-7/W55) | 2.34 | 2.20 | 2.10 | 2.34 | |
Heating capacity (A-15/W35) | kW | 4.7 | 6.6 | 8.3 | 9.4 |
Heating power input (A-15/W35) | kW | 1.42 | 2.21 | 2.87 | 2.91 |
COP (A-15/W35) | 3.31 | 2.99 | 2.89 | 3.23 | |
Heating capacity (A-15/W55) | kW | 4.4 | 6.1 | 7.6 | 8.8 |
Heating power input (A-15/W55) | kW | 2.23 | 3.39 | 4.17 | 4.46 |
COP (A-15/W55) | 1.97 | 1.80 | 1.82 | 1.97 | |
Cooling capacity (A35/W7) | kW | 5.6 | 7.95 | 9.64 | 11.20 |
Cooling power input (A35/W7) | kW | 1.52 | 2.32 | 2.87 | 3.04 |
EER (A35/W7) | 3.68 | 3.43 | 3.36 | 3.68 | |
Operating ambient temperature | .+43 ~ --25 | ||||
Max. water temp. | ℃ | 60 | |||
Rated water temp. | ℃ | 55 | |||
water flow | m3/h | 1 | 1.50 | 1.90 | 2.20 |
pressure drop | Kpa | 18 | 22 | 24 | 24 |
Net weight | kg | 72 | 90 | 96 | 106 |
Gross weight | kg | 84 | 105 | 111 | 120 |
Noise | dB(A) | 50 | 52 | 53 | 54 |
Pipe connection | mm | 3/4 inch | 1 inch | ||
Power supply | 220V/1PH/50Hz | 220V/1PH/50Hz | 220V/1PH/50Hz 380V/3PH/50Hz | ||
Net size | mm | 1110*450*700 | 1110*450*850 | 1110*450*850 | |
Package size | mm | 1160*490*850 | 1200*520*990 | 1200*520*990 | |
Compressor | brand | Mitsubishi | |||
quantity | 1 | ||||
Condenser | plate heat exchanger | ||||
Evaporator | Louverd&hydrophilic fin-tubes | ||||
4-way valve | Yes | ||||
Flow switch | Yes | ||||
Circulation pump | Built-in energy clasee A water pump | ||||
Expansion valve | Electionic expansion valve | ||||
DC Fan motor | 80W | 80W | 80W | 80W | |
High pressure switch | 4.2/3.6MPa | ||||
Low pressure switch | 0.02/0.15MPa | ||||
Working mode | cooling, heating, hot water, cooling+hot water, heating+hot water | ||||
Refrigerant | R32/ r410a |
1. Unit working temperature : -25℃ to 43℃
2. Test condition:
* Ambient temp: 7℃/6℃, water inlet/outlet: 30℃/35℃
** Ambient temp: 2℃/1℃, water inlet/outlet: 30℃/35℃
*** Ambient temp: 35℃, water inlet/outlet: 7℃/12℃
**** Ambient temp: 35℃, water inlet/outlet: 18℃/23℃
3. Hot water supply: the volume of hot water heated from 15℃ to 55℃ at ambient temp 15℃.
4. The above is the basic configuration. Water pump is included in.
DC Inverter Air to Water heat pump( monoblock) | |||||
Model | FAD-02 | FAD-03-1 | FAD-03 | FAD-04 | |
Heating capacity (A7/W35) | kW | 8.2 | 11.0 | 13.9 | 15.0 |
Heating power input (A7/W35) | kW | 1.38 | 2.07 | 2.69 | 2.76 |
COP (A7/W35) | 5.94 | 5.31 | 5.17 | 5.43 | |
Heating capacity (A7/W55) | kW | 6.1 | 9.2 | 10.9 | 12.2 |
Heating power input (A7/W55) | kW | 1.95 | 2.73 | 3.79 | 3.90 |
COP (A7/W55) | 3.13 | 3.37 | 2.88 | 3.13 | |
Heating capacity (A2/W35) | kW | 6.3 | 9.1 | 11.2 | 12.6 |
Heating power input (A2/W35) | kW | 1.32 | 2.02 | 2.53 | 2.64 |
COP (A2/W35) | 4.77 | 4.50 | 4.43 | 4.77 | |
Heating capacity (A2/W55) | kW | 5.7 | 7.9 | 10.2 | 11.4 |
Heating power input (A2/W55) | kW | 1.88 | 2.76 | 3.65 | 3.76 |
COP (A2/W55) | 3.03 | 2.86 | 2.79 | 3.03 | |
Heating capacity (A-7/W35) | kW | 5.3 | 6.71 | 9.6 | 10.6 |
Heating power input (A-7/W35) | kW | 1.42 | 1.82 | 2.72 | 2.84 |
COP (A-7/W35) | 3.73 | 3.69 | 3.53 | 3.73 | |
Heating capacity (A-7/W55) | kW | 5.1 | 7.7 | 9.1 | 10.2 |
Heating power input (A-7/W55) | kW | 2.18 | 3.5 | 4.33 | 4.36 |
COP (A-7/W55) | 2.34 | 2.20 | 2.10 | 2.34 | |
Heating capacity (A-15/W35) | kW | 4.7 | 6.6 | 8.3 | 9.4 |
Heating power input (A-15/W35) | kW | 1.42 | 2.21 | 2.87 | 2.91 |
COP (A-15/W35) | 3.31 | 2.99 | 2.89 | 3.23 | |
Heating capacity (A-15/W55) | kW | 4.4 | 6.1 | 7.6 | 8.8 |
Heating power input (A-15/W55) | kW | 2.23 | 3.39 | 4.17 | 4.46 |
COP (A-15/W55) | 1.97 | 1.80 | 1.82 | 1.97 | |
Cooling capacity (A35/W7) | kW | 5.6 | 7.95 | 9.64 | 11.20 |
Cooling power input (A35/W7) | kW | 1.52 | 2.32 | 2.87 | 3.04 |
EER (A35/W7) | 3.68 | 3.43 | 3.36 | 3.68 | |
Operating ambient temperature | .+43 ~ --25 | ||||
Max. water temp. | ℃ | 60 | |||
Rated water temp. | ℃ | 55 | |||
water flow | m3/h | 1 | 1.50 | 1.90 | 2.20 |
pressure drop | Kpa | 18 | 22 | 24 | 24 |
Net weight | kg | 72 | 90 | 96 | 106 |
Gross weight | kg | 84 | 105 | 111 | 120 |
Noise | dB(A) | 50 | 52 | 53 | 54 |
Pipe connection | mm | 3/4 inch | 1 inch | ||
Power supply | 220V/1PH/50Hz | 220V/1PH/50Hz | 220V/1PH/50Hz 380V/3PH/50Hz | ||
Net size | mm | 1110*450*700 | 1110*450*850 | 1110*450*850 | |
Package size | mm | 1160*490*850 | 1200*520*990 | 1200*520*990 | |
Compressor | brand | Mitsubishi | |||
quantity | 1 | ||||
Condenser | plate heat exchanger | ||||
Evaporator | Louverd&hydrophilic fin-tubes | ||||
4-way valve | Yes | ||||
Flow switch | Yes | ||||
Circulation pump | Built-in energy clasee A water pump | ||||
Expansion valve | Electionic expansion valve | ||||
DC Fan motor | 80W | 80W | 80W | 80W | |
High pressure switch | 4.2/3.6MPa | ||||
Low pressure switch | 0.02/0.15MPa | ||||
Working mode | cooling, heating, hot water, cooling+hot water, heating+hot water | ||||
Refrigerant | R32/ r410a |
1. Unit working temperature : -25℃ to 43℃
2. Test condition:
* Ambient temp: 7℃/6℃, water inlet/outlet: 30℃/35℃
** Ambient temp: 2℃/1℃, water inlet/outlet: 30℃/35℃
*** Ambient temp: 35℃, water inlet/outlet: 7℃/12℃
**** Ambient temp: 35℃, water inlet/outlet: 18℃/23℃
3. Hot water supply: the volume of hot water heated from 15℃ to 55℃ at ambient temp 15℃.
4. The above is the basic configuration. Water pump is included in.