Name:Air source heat pump/Air to water heat pump(60degree)heating+hot water |
Model | unit | FA-015 | FA-02 |
Rated heating capacity | KW | 4.83 | 7.1 |
BTU | 16485 | 24232 |
Hot water supply | T/h | 0.1 | 0.15 |
Average heating input power | KW | 1.15 | 1.7 |
Rated heating input current | A | 4.71 | 7.11 |
Max outlet water temp | ℃ | 60℃ |
COP |
| 4.2 | 4.18 |
Power | V/Hz | 220-240V/50HZ |
Nosie | dB(A) | 45 | 47 |
Dimension | Width | mm | 930 | 1000 |
Deepth | mm | 280 | 300 |
Height | mm | 550 | 620 |
Unit weight | KG | 75 | 85 |
Throttling type |
| Electronic expansion valves/thermal expansion valves |
Refrigerant |
| R410A |
Working air temp range |
| – 20℃~45℃ |
Compressor | Type |
| Panasonic,hitachi |
Security functions |
| Built-in protection device overheating protection, sequence protection, undervoltage protection, delay protect |
Air source heat exchanger | Type |
| Finned heat exchange |
Qty | piece | 1 |
Fan type |
| Axial big twist Angle fan |
Motor power | KW | 0.04 | 0.05 |
Hot water side heat exchange | Type |
| Efficient tube to tube heat exchanger/tube in shell heat exchanger |
Water flow | m3/H | 0.84 | 1.22 |
Water pressure down | kPa | 20 | 20 |
Pipe size | Inch | 3∕4 |
Water side max working pressure | kPa | 1000 |
Remarks:the test conditions of above parameter:dry bulb temp is 20℃.wet buld temp is 17℃.inlet water temp is 15℃.outlet water temp is 60℃ |